Centralis Steel solve tube OPGW cable

Centralis Steel solve tube OPGW cable

Formularium:

    OPGW rudentes optici maxime adhibentur in lineis campestribus 110KV, 220KV, 550KV, et plerumque in lineis recentibus constructis propter factores ut lineae virtutis outages et salus adhibentur.

Velox Detail

Parameter Tabula

Product Tags

asd*

Applicationem:

1.OPGW rudentes optici maxime adhibentur in lineis campestribus 110KV, 220KV, 550KV, et plerumque in lineis recentibus constructis propter factores ut lineae virtutis outages et salus adhibentur.
2. Lineae cum alta intentione 110kv excedentem maiorem latitudinem habent (vulgo supra 250M).
3. Facile est ponere, facile solvere problema de linea transitu, eiusque characteribus mechanicis occurrere rectae magnae transitus;
4. Tegumen OPGW est armatura metallica, quae altam intentionem corrosionis electricae et degradationis non afficit.
5. OPGW in constructione distrahi debet, et potentia amissa relative magna est, ergo OPGW in lineis supra 110kv noviter exstructis.

Marisque:

● Dimeterium funem parvum, leve pondus, humilis ad turrim addito onere;
● Tubus chalybeus in funeri centro collocat, nulla secunda lassitudo mechanica damnum.
Repugnantia ad latus pressura, torsio et distrahens (stratum unum).

Standard

ITU-TG.652 Characteres unius modi fibrorum opticorum.
ITU-TG.655 Characteres non-nullae disper- siones unico modo fibrarum opticarum exhibentur.
EIA/TIA598 B Col- codicem fibra retinacula optica.
IEC 60794-4-10 Funes optici aerei per lineas potentias electricas-familiae specificationem pro OPGW.
IEC 60794-1-2 retinae fibra optica —pars experimenti ratio.
IEEE1138-2009 IEEE Standard for testing and performance for optical ground wire for use on electric utilitate lineis virtutis.
IEC 61232 Aluminium - Clad filum ferro ad electrica causa.
IEC60104 Aluminium magnesium stannum filum pro capite linea conductores.
IEC 61089 Filum rotundum concentricis iacebat caput conductores electrica subductis.

Technical Parameter

Typical design for Single Layer

Specification Fibra comitis Diameter (mm) Pondus (kg/km) RTS (kN) Brevis Circuitus (KA2s)
OPGW-32(40.6; 4.7) 12 7.8 243 40.6 4.7
OPGW-42(54.0;8.4) 24 9 313 54 8.4
OPGW-42(43.5;10.6) 24 9 284 43.5 10.6
OPGW-54(55.9;17.5) 36 10.2 394 67.8 13.9
OPGW-61(73.7; 175) 48 10.8 438 73.7 17.5
OPGW-61(55.1;24.5) 48 10.8 358 55.1 24.5
OPGW-68(80.8; 21.7) 54 11.4 485 80.8 21.7
OPGW-75(54.5;41.7) 60 12 459 63 36.3
OPGW-76(54.5;41.7) 60 12 385 54.5 41.7

Typical design for Double Layer

Specification Fibra comitis Diameter (mm) Pondus (kg/km) RTS (kN) Brevis Circuitus (KA2s)
OPGW-96 (121.7; 42.2) 12 13 671 121.7 42.2
OPGW-127 (141.0; 87.9) 24 15 825 141 87.9
OPGW-127(77.8; 128.0) 24 15 547 77.8 128
OPGW-145(121.0;132.2) 28 16 857 121 132.2
OPGW-163 (138.2; 183.6) 36 17 910 138.2 186.3
OPGW-163(99.9; 213.7) 36 17 694 99.9 213.7
OPGW-183 (109.7; 268.7) 48 18 775 109.7 268.7
OPGW-183 (118.4; 261.6) 48 18 895 118.4 261.6

Nota:
1. Solum pars supra caput terrae filum opticum in tabula recensentur.Rudentes cum aliis determinationibus quaeri possunt.
2. Cables cum fibris unius modi vel multimodis range suppleri possunt.
3.Specially designed Cable structure is available on request.
4.Cables potest suppleri siccis core vel semi siccum core