IEC/BS Standard 18-30kV-XLPE Insulated MV Medius intentionis potentiae Cable

IEC/BS Standard 18-30kV-XLPE Insulated MV Medius intentionis potentiae Cable

Formularium:

    Funes nuclei singuli ad distribuendum vim electricam cum voltage nominali Uo/U ab 3.8/6.6KV ad 19/33KV et frequentiam 50Hz ordinantur.Aptissima sunt ad institutionem maxime in potestate copiarum statio, intus et in ductus funiculi, foris, subterraneis et in aquis, necnon ad institutionem in fune scutariorum pro industrias, switchboards et stationes potentiae.

Velox Detail

Parameter Tabula

Product Tags

Applicationem:

Apta energiae retia ut stationes potentiae.Nam in elit lorem, et suscipit velit.Placere note: Vagina exterior rubra potest prona ad flori cum UV radiis exposita.

Signa:

Flamma propagatio ad BS EN60332
BS6622
IEC 60502

Characteres :

Conductor: annealed rotundum cuprum conductorem vel aluminium conductorem compactum substratum
Insulatio: vinculum crucis polyethylene (XLPE)
Metallic screen: singula aut altiore tape screen
Lectisternia: polyvinyl chloride (PVC)
Armouring: Steel Wire Armor (SWA), Aluminium Wire Armor (AWA)
Vaginam: PVC vaginam exteriorem
Vaginae color: Niger

Data electrica:

Maximum conductor operating temperatus: XC° C
Maximum screen operating temperatus: LXXX°C
Maximum conductor temperatus in SC: CCL°C
Condiciones in trifolii formatione ponunt ut infra:
Solum scelerisque resistivity: 120˚C.Cm/Watt
Altitudo sepultura: 0.5m
Humus temperatus: 15°C
Temperatus aeris: 25°C
Frequentia: 50Hz

Constructio Codicis:

N2XSY: PVC vaginatus nucleus aeneus funis
N2XS2Y: Polyethylene (PE) nucleum aeneum vaginatum
NA2XSY: PVC vaginatus nucleum unum aluminium funem
NA2XS2Y: PE vaginatus nucleus singularis aluminii cable
N2XS(F)2Y: waterblocked PE vaginatum unum nucleum aeris funem
NA2XS(F)2Y: waterblocked PE vaginatum unum nucleum aluminium funem
NA2XS(FL)2Y: PE vaginatus cori unius aluminii funem cum duali waterblocking stratis

Single-core-18/30 kV

Nominal area conductor Conductor diam Nulla crassities Nominal altiore diametri Maximum altiore diametri Proximus funem pondus kg / km Minimum inflexio radii
mm² mm mm mm mm Cu Al mm
1x 35 7.0 8.0 32.3 33.3 1315 1098 466
1x 50 8.2 8.0 33.7 34.7 1512 1198 486
1x 70 9.9 8.0 35.6 36.6 1792 1350 512
1x 95 11.5 8.0 37.4 38.4 2114 1516 538
1×120 12.9 8.0 38.8 39.8 2406 1650 558
1×150 14.2 8.0 40.1 41.1 2742 1798 576
1×185 16.2 8.0 42.3 43.3 3176 2010 606
1×240 18.2 8.0 44.5 45.5 3788 2277 640
1×300 21.2 8.0 47.7 48.7 4502 2613 680
1×400 23.4 8.0 49.8 50.8 5534 3015 710
1×500 27.3 8.0 54.2 55.2 6662 3513 710
1×630 30.5 8.0 55.4 57.4 7820 3953 775

Three-cores-18/30 kV

Nominal area conductor Conductor diam Nulla crassities Nominal altiore diametri Maximum altiore diametri Proximus funem pondus kg / km Minimum inflexio radii
mm² mm mm mm mm Cu Al mm
3x 35 7.0 8.0 61.4 62.8 4138 3482 873
3x 50 8.2 8.0 68.9 69.9 6273 5328 980
3x 70 9.9 8.0 72.8 73.8 7319 5997 1030
3x 95 11.5 8.0 76.5 77.5 8469 6674 1080
3×120 12.9 8.0 79.7 80.7 9575 7308 1130
3×150 14.2 8.0 82.7 83.7 10806 7972 1170
3× 185 16.2 8.0 87.4 88.4 12420 8925 1240
3×240 18.2 8.0 91.9 92.9 14563 10030 1300

Armati tres coros-18/30 kV

Nominal area conductor Conductor diam Nulla crassities Nominal altiore diametri Maximum altiore diametri Proximus funem pondus kg / km Minimum inflexio radii
mm² mm mm mm mm Cu Al mm
3x 35 7.0 8.0 67.3 69.3 6981 6330 956
3x 50 8.2 8.0 74.2 75.2 8212 7267 1050
3x 70 9.9 8.0 78.1 79,1 9360 8038 1100
3x 95 11.5 8.0 81.8 82.8 10610 8815 1160
3×120 12.9 8.0 85.0 86.0 11812 9545 1200
3×150 14.2 8.0 88.0 89.0 13136 10302 1240
3× 185 16.2 8.0 92.7 93.7 14890 11395 1310
3×240 18.2 8.0 97.2 98.2 17166 12630 1370