IEC 60502-2---- Potentia funes cum velitationibus extrusis eorumque accessoriis pro voltages aestimandis ab 1 kv (Um = 1.2 kV) usque ad 30 kV (Um = 36 kV) - Pars 2: Cables pro voltages ex 6 kV aestimatis ( Um = 7.2 kv) usque ad 30 kV (Um = 36 kV)
6.35/11kV, 19/33kV
Conductor Phase: Classis II Aluminium destitutus circularis compactus
Conductor Screen: Extruded semi-conductive layer
Insulatio: XLPE (Cross-coniunctum polyethylene)
Nulla Screen: Extruded semi-products iacuit
Metallic screen: filum aeneum screen vel taenia taenia
Separator: Semi-products Tumor tape
Exterior Vagina: HDPE (High Densitas polyethylene)
Support Conductor:Fila ferro Galvanized
Insulae core: Red, Yellow & Blue core notati tape
Outed vaginae nigrae
Temperatus operans: 90°C XLPE
Temperature Range: -20°C PE vaginae m
Brevis Circuitus Temperature(5 seconds maximam durationem): 250°C XLPE
Radius tendentes: XV x diametri altiore
Quales rudentes efficimus utendo materia summus finis;
Dives usus bigas sciens quid petis:
Planta cum bonis facultatibus et capacitatibus praestandi in tempore partus;
Numerus Cores x Nominal Cross Section | Phase Conductor | Nuntius Suspensionis Unit | Continua Current Rating in 300°C Ambient Temp. | ||||
Stranding | Nominal Area | Maxime Conductor Resistentia | Stranding | Nominal Area | Fractio Load | ||
No.×mm² | No.×mm | mm² | Ω/Km | No.×mm | mm² | kN | A |
3X50 + 1X25 | 19/1.78 | 50 | 0.641 | 7/3.0 | 50 | 60 | 116 |
3X70 + 1X50 | 19/.14 | 70 | 0.443 | 7/3.15 | 50 | 62 | 210 |
3X95+ 1X50 | 19/2.52 | 95 | 0.32 | 7/3.0 | 50 | 60 | 173 |
3X185+1X120 | 37/2.52 | 185 | 0.164 | 7/4.67 | 120 | 150 | 259 |
3X150 +X50 | 37/2.25 | 150 | 0.206 | 7/3.15 | 50 | 62 | 365 |
3X240 +X50 | 61/2.25 | 240 | 0.125 | 7/3.15 | 50 | 62 | 500 |
Numerus Cores x Nominal Cross Section | Phase Conductor | Nuntius Suspensionis Unit | Continua current rating in CCC° C ambientium temp | ||||
Stranding | Nominal Area | Maxime Conductor Resistentia | Stranding | Nominal Area | Fractio Load | ||
No.×mm² | No.×mm | mm² | Ω/Km | No.×mm | mm² | kN | A |
3X50 + 1X50 | 19/1.78 | 50 | 0.641 | 7/3.0 | 50 | 60 | 165 |
3X150+ 1X50 | 37/2.25 | 150 | 0.206 | 7/3.0 | 50 | 60 | 315 |
3X185+1X70 | 37/2.52 | 185 | 0.164 | 7/3.57 | 70 | 91 | 355 |
3X70 +X50 | 19/2.14 | 7 | 0.443 | 7/3.15 | 50 | 62 | 250 |
3X150 +X50 | 37/2.25 | 150 | 0.206 | 7/3.15 | 50 | 62 | 370 |